Hello! now
HK In FortuneFree Shipping Over$200
Follow Us:

Humidity, Moisture Sensors

Manufacturer Series Package/Case Packaging Part Status Sensor Type Humidity Range Output Accuracy Response Time Sensitivity Voltage - Supply Output Type Mounting Style Operating Temperature Grade Qualification Supplier Device Package

Reset All
Apply All
Result
Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Part Status Sensor Type Humidity Range Output Accuracy Response Time Sensitivity Voltage - Supply Output Type Mounting Style Operating Temperature Grade Qualification Supplier Device Package
A/RH2-R-LCD-010

A/RH2-R-LCD-010

Relative Humidity, Room, Humidit

Automation Components, Inc.

1 -
RFQ
A/RH2-R-LCD-010

Datasheet

- Module Tape & Box (TB) Active Humidity 0 ~ 100% RH 0V ~ 10V ±2% RH - - 20 ~ 28VAC, 18 ~ 40VDC Analog Voltage Chassis Mount 0°C ~ 40°C - - -
A/RH2-R-LCD-420

A/RH2-R-LCD-420

Relative Humidity, Room, Humidit

Automation Components, Inc.

1 -
RFQ
A/RH2-R-LCD-420

Datasheet

- Module Tape & Box (TB) Active Humidity 0 ~ 100% RH 4mA ~ 20mA ±2% RH - - 20 ~ 28VAC, 18 ~ 40VDC Analog Current Chassis Mount 0°C ~ 40°C - - -
A/RH2-TT100-O-4X-1

A/RH2-TT100-O-4X-1

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

1 -
RFQ
A/RH2-TT100-O-4X-1

Datasheet

- Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH 1V ~ 5V ±2% RH 20 s - 18 ~ 28VAC, 12 ~ 40VDC Analog Voltage Chassis Mount -40°C ~ 60°C - - Module
A/RH2-TT100-O-4X-4

A/RH2-TT100-O-4X-4

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

1 -
RFQ
A/RH2-TT100-O-4X-4

Datasheet

- Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH 4mA ~ 20mA ±2% RH 20 s - 18 ~ 28VAC, 15 ~ 40VDC Analog Current Chassis Mount -40°C ~ 60°C - - Module
A/RH2-R-LCD-05

A/RH2-R-LCD-05

Relative Humidity, Room, Humidit

Automation Components, Inc.

1 -
RFQ
A/RH2-R-LCD-05

Datasheet

- Module Tape & Box (TB) Active Humidity 0 ~ 100% RH 0V ~ 5V ±2% RH - - 20 ~ 28VAC, 12 ~ 40VDC Analog Voltage Chassis Mount 0°C ~ 40°C - - -
A/RH3-R-LCD-010-NIST

A/RH3-R-LCD-010-NIST

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

1 -
RFQ
A/RH3-R-LCD-010-NIST

Datasheet

- Module Tape & Box (TB) Active Humidity 0 ~ 100% RH 0V ~ 10V ±3% RH - - 20 ~ 28VAC, 18 ~ 40VDC Analog Voltage Chassis Mount 0°C ~ 40°C - - -
A/RH2-TT1K-O-4X-2

A/RH2-TT1K-O-4X-2

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

1 -
RFQ
A/RH2-TT1K-O-4X-2

Datasheet

- Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH 2V ~ 10V ±2% RH 20 s - 18 ~ 28VAC, 18 ~ 40VDC Analog Voltage Chassis Mount -40°C ~ 60°C - - Module
A/RH2-TT1K-O-4X-1

A/RH2-TT1K-O-4X-1

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

1 -
RFQ
A/RH2-TT1K-O-4X-1

Datasheet

- Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH 1V ~ 5V ±2% RH 20 s - 18 ~ 28VAC, 12 ~ 40VDC Analog Voltage Chassis Mount -40°C ~ 60°C - - Module
A/RH3-TTM1K-D-4X-4

A/RH3-TTM1K-D-4X-4

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

1 -
RFQ
A/RH3-TTM1K-D-4X-4

Datasheet

- Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH 4mA ~ 20mA ±3% RH 20 s - 18 ~ 28VAC, 15 ~ 40VDC Analog Current Chassis Mount -40°C ~ 60°C - - -
HG80I

HG80I

Humidistat, Duct, Internal Setpo

Automation Components, Inc.

1 -
RFQ
HG80I

Datasheet

- Module Tape & Box (TB) Active Humidity 0 ~ 100% RH - ±4% RH 120 s - - SPDT Chassis Mount 0°C ~ 60°C - - -
A/RH3-TTM1K-O-4X-4

A/RH3-TTM1K-O-4X-4

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

1 -
RFQ
A/RH3-TTM1K-O-4X-4

Datasheet

- Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH 4mA ~ 20mA ±3% RH 20 s - 18 ~ 28VAC, 15 ~ 40VDC Analog Current Chassis Mount -40°C ~ 60°C - - Module
A/RH3-TTM100-O-4X-4

A/RH3-TTM100-O-4X-4

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

1 -
RFQ
A/RH3-TTM100-O-4X-4

Datasheet

- Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH 4mA ~ 20mA ±3% RH 20 s - 18 ~ 28VAC, 15 ~ 40VDC Analog Current Chassis Mount -40°C ~ 60°C - - Module
A/RH2-TTM1K-R2-4

A/RH2-TTM1K-R2-4

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

1 -
RFQ
A/RH2-TTM1K-R2-4

Datasheet

- Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH 4mA ~ 20mA ±2% RH 20 s - 18 ~ 28VAC, 15 ~ 40VDC Analog Current Chassis Mount -40°C ~ 60°C - - -
A/RH2-TTM1K-R-4

A/RH2-TTM1K-R-4

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

1 -
RFQ
A/RH2-TTM1K-R-4

Datasheet

- Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH 4mA ~ 20mA ±2% RH 20 s - 18 ~ 28VAC, 15 ~ 40VDC Analog Current Chassis Mount -40°C ~ 60°C - - -
A/RH2-TTM1K-R-2

A/RH2-TTM1K-R-2

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

1 -
RFQ
A/RH2-TTM1K-R-2

Datasheet

- Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH 2V ~ 10V ±2% RH 20 s - 18 ~ 28VAC, 18 ~ 40VDC Analog Voltage Chassis Mount -40°C ~ 60°C - - -
A/RH2-TTM100-R-4

A/RH2-TTM100-R-4

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

1 -
RFQ
A/RH2-TTM100-R-4

Datasheet

- Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH 4mA ~ 20mA ±2% RH 20 s - 18 ~ 28VAC, 15 ~ 40VDC Analog Current Chassis Mount -40°C ~ 60°C - - -
A/RH2-TTM1K-R2-2

A/RH2-TTM1K-R2-2

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

1 -
RFQ
A/RH2-TTM1K-R2-2

Datasheet

- Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH 2V ~ 10V ±2% RH 20 s - 18 ~ 28VAC, 18 ~ 40VDC Analog Voltage Chassis Mount -40°C ~ 60°C - - -
A/RH2-TTM1K-R2-1

A/RH2-TTM1K-R2-1

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

1 -
RFQ
A/RH2-TTM1K-R2-1

Datasheet

- Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH 1V ~ 5V ±2% RH 20 s - 18 ~ 28VAC, 12 ~ 40VDC Analog Voltage Chassis Mount -40°C ~ 60°C - - -
A/RH2-TTM1K-D-BB-2

A/RH2-TTM1K-D-BB-2

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

1 -
RFQ
A/RH2-TTM1K-D-BB-2

Datasheet

- Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH 2V ~ 10V ±2% RH 20 s - 18 ~ 28VAC, 18 ~ 40VDC Analog Voltage Chassis Mount -40°C ~ 60°C - - -
A/RH2-TTM100-D-BB-4

A/RH2-TTM100-D-BB-4

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

1 -
RFQ
A/RH2-TTM100-D-BB-4

Datasheet

- Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH 4mA ~ 20mA ±2% RH 20 s - 18 ~ 28VAC, 15 ~ 40VDC Analog Current Chassis Mount -40°C ~ 60°C - - -
Total 1335 Record«Prev1... 5556575859606162...67Next»
HK In Fortune

Search

HK In Fortune

Products

HK In Fortune

Phone

HK In Fortune

User